-------------------------------------------------------------------------- ReadWin 2000 -------------------------------------------------------------------------- 1. Installation 2. Hardware and software requirements (additional to chapter 1.4 of the manual) 3. Conversion of the ReadWin 16Bit database 4. Release notes -------------------------------------------------------------------------- 1. Installation - Place CD into drive - If autostart is active then the installation is automatically started. If this is not the case go to the directory "..\install" on the CD and start "Setup.exe". - Follow the installation programme instructions. - Start ReadWin 2000. ATTENTION: If you install ReadWin 2000 to a Windows 2000 / XP PC with restricted user access rights, you must change the installation directory to a directory outside the "Program Files" directory (e.g. from "C:\Program Files\....\ReadWin32" to "C:\ReadWin2000"). Note: At the end of the installation you may get the following message: "The installer has detected that the hardware associated with this package is not currently plugged-in to the computer. Please plug in the hardware with this package after the installation has completed successfully". This message can be ignored (the setup program is installing a USB/RS232 driver for our devices). -------------------------------------------------------------------------- 2. Hardware and software requirements (additional to chapter 1.4 of the manual) Supported operating systems: Windows 2000 / XP / Vista -------------------------------------------------------------------------- 3. Conversion of the ReadWin 16Bit database Please see chapter 11 of the manual or start the online help -------------------------------------------------------------------------- 4. Release notes: ========================================================================== V1.27.15.0 20.02.2017 - Auto detect for ReadWin 2000 QST fixed - Hotfix readout RSG40 Treiber/DLL Updates: - TMR3x: lower range from -32°F to -58°F changed - RMx621 - RSG40 ========================================================================== V1.27.14.0 06.12.2016 Internal version ========================================================================== V1.27.13.0 17.08.2016 Internal version ========================================================================== V1.27.12.0 08.01.2016 Driver updates (only for set-up required): - RMC/RMS621 - RIA452 ========================================================================== V1.27.11.0 30.06.2014 Driver updates (only for set-up required): - TMT162 - Flowphant - Memograph M RSG40: GMA601A ========================================================================== V1.27.10.0 29.07.2013 Bug fixing / modifications: - new USB driver for TXU10A (V2) Driver updates (only for set-up required): - TMT80 - Memograph M RSG40: GMU00xA ========================================================================== V1.27.9.0 21.05.2013 Bug fixing / modifications: - Failed to export CSV/Excel export fixed (If too many channels) Driver updates (only for set-up required): - Memograph M CVM40: GMP00xA ========================================================================== V1.27.8.0 03.12.2012 Bug fixing / modifications: - ReadWin 2000 + QST: modifications for new label customer (Config file improved) Driver updates (only for set-up required): - Memograph M RSG40: GMU00xA - TPC00xA, TPC10xA - All PC programable temperature devices (year 2013 problem) ========================================================================== V1.27.7.0 06.08.2012 Driver updates (only for set-up required): - Memograph M - Memograph M CVM40 ========================================================================== V1.27.6.0 28.11.2011 - Readout: Problem fixed Memograph M Mobus Master and counters - Readout: Problem fixed Ecograph T and events after setup change Driver updates (only for set-up required): - RMC/RMS621 - Memograph M (Japanese) - GLY10DA ========================================================================== V1.27.5.0 07.06.2011 Bug fixing / modifications: - Bargraph visualisation: problem fixed if no digital input was used (--> no dialog size optimization) - new E+H logo Driver updates (only for set-up required): - RMC/RMS621 ========================================================================== V1.27.4.0 31.03.2011 Bug fixing / modifications: - Read out: Problem with Ecograph T operation time fixed (wrong display format) - Display instantaneous values: transmission error when display digital states. This is only a problem of V1.27.3.0. - Database reorganization optimized. ========================================================================== V1.27.3.0 16.02.2011 Bug fixing / modifications: - Bugfix: COM80.dll TC compensation problem fixed - Display stored values Memograph M: wrong checksum error messages fixed - Changing the TMT181 interface settings could cause an excpetion - Automatic instantaneous export for eSight - It was not possible to read out the CVM40 via SD card - Help updated - MEMV200001217 fixed: Memograph M: Setup/ Online parameters: Parameter description improved Driver updates (only for set-up required) - Memograph M GMU00xA V2.10.00 ========================================================================== V1.27.2.0 14.10.2010 Bug fixing / modifications: - Automatic export Memograph M batch reports fixed - Translations fixed (Remote control) Driver updates (only for set-up required) - FML007A, - RMS621, RMC621 (ÄA W10941) ========================================================================== V1.27.1.0 11.06.2010 New functions/features: - DynDNS support (Domain Name instead of IP address) Driver updates (only for set-up required) - TMT80 ========================================================================== V1.27.0.0 09.04.2010 New functions/features: - TMT80 Bug fixing / modifications: - Problem fixed with auto detection of temperature units - Add on SMC32 help fixed Driver updates (only for set-up required) - GMA201A - Memograph M - Ecograph T - TMT80 ========================================================================== V1.26.1.0 05.02.2010 Driver updates (only for set-up required) - Memograph M - Memograph GLY30xA ========================================================================== V1.26.0.0 17.11.2009 Bug fixing / modifications: - Automatic export/print out: fixed a problem when read out manually - Install program updatet: now supports Windows 7 (Driver Installation) - Problem when displaying Memolog RÜB data fixed. Driver updates (only for set-up required) - CVM40 - Ecograph T - Memograph M ========================================================================== V1.25.5.0 27.05.2009 Bug fixing / modifications: - Remote control for RMM621 tele alarm (new firmware is required) modified Driver updates (only for set-up required) - RMC621 - RMS621 - RMM621 ========================================================================== V1.25.4.0 14.05.2009 Bug fixing / modifications: - Remote control for RMM621 tele alarm (new firmware is required) - Installation program modified: the version 1.25.3.0 did uninstall the USB driver from the FXA291. ========================================================================== V1.25.3.0 29.04.2009 Bug fixing / modifications: - Installation modified (new 64Bit USB Drivers Memograph M and Ecograph T for XP/Vista 64Bit - ASP2000 and Liquiport2000: release code added - Automatic: message receive via GSM Modem improved - Function “Automatic interrupted for maintenance purposes” fixed Driver updates (only for set-up required) - RMM621 - RMC621 - RMS621 ========================================================================== V1.25.2.0 27.02.2009 Bug fixing / modifications: - CZ translation modified - MEMV200000983: Memograph M: Problem when displaying batches fixed Driver updates (only for set-up required): - FML621 - Memograph GLM106A - RMC/RMS621 - TMT162 - Memograph M - Ecograph T ========================================================================== V1.25.1.0 12.01.2009 Bug fixing / modifications: - Read out Ecograph T: fixed a bug which was added to the version 1.25.0.0 Driver updates (only for set-up required) - RMC621 - RMS621 ========================================================================== V1.25.0.0 09.12.2008 New functions/features: - Memograph M V2 supported (Read out, Visualization, Print out, Storage, Export and Remote Control modified) - Display unit details: Ecograph T / Memograph M: application number added Bug fixing / modifications: - MEMV200000073: Firmware update Memograph M via serial interface fixed - Ecograph T / Read out: problem with units fixed - Display stored values: the state of the checkboxes min/max/average was not stored - MEMV200000751: Setup: quick help fixed Driver updates (only for set-up required) - Memograph M V2 - Ecograph T - RIA452 ========================================================================== V1.24.3.0 28.10.2008 Bug fixing / modifications: - Read out stored data: Memograph M: high speed storage fixed Driver updates (only for set-up required) - Ecograph T ========================================================================== V1.24.1.0 02.10.2008 Bug fixing / modifications: - Export to csv/xls fixed Driver updates (only for set-up required) - VCOM: Bugfixing for TMR3x and TSM470/480 - RIA452 ========================================================================== V1.24.0.0 10.07.2008 Bug fixing / modifications: - Some preparations for new products - Memograph M Defect 652 fixed - Japanese translation updated Driver updates (only for set-up required) - TMT162/TMT142. - Memograph M GMU00xA (supports new option "Energy") ========================================================================== V1.23.2.0 19.02.2008 Bug fixing / modifications: - Japanese version modified - RMM621 / export stored values: problem fixed - User management: problem fixed - Automatic: not all error were displayed - Memograph M / firmware update: problem fixed when using unit address not equal to 01 - Time synchronization problem fixed (Memograph M / Ecograph T) Driver updates (only for set-up required) - Memograph M - Ecograph T ========================================================================== V1.23.1.0 29.11.2007 Bug fixing / modifications: - RMM621: automatic export of stored data was not possible - Firmware update Memograph M / Ecograph T: when the unit was protected by a release code it was not possible to update the firmware - Memograph M / Setup: problem with the user administration fixed Driver updates (only for set-up required) - Ecograph T V2 - Memograph M (options Profibus DP, Modbus) - RIA452 - Liquiport2000/ASP2000 Peristaltic - RMS621/RMC621 OEM - FCX01xA ========================================================================== V1.23.0.0 30.10.2007 New functions/features: - New demo data and configuration files for Memograph M milk pasteurisation (see CD-ROM) - New start up screen - Read out measured values using PC card: it is now possible to select the files which should be read out (only available for Ecograph T and Memograph M) Bug fixing / modifications: - Several modifications for Japanese language - Transmit program RMM621/FML621: Options "Device set-up" and "Counter conditions" disabled - Store/save measured values: Delete data modified - Display measured values from database: fixed a problem when using extreme zoom values - Display measured values from database: help lines fixed - Ecograph T / online setup: problem fixed - Modem detection: problem fixed with high speed modem - Read out measured values / Ecograph T: problem fixed - RMC621/RMS621: setup problem fixed (FCSX0xa and FCUX0xA) - new USB Driver for Ecograph T and Memograph M (Vista) Driver updates (only for set-up required) - Ecograph T V2 - Memograph M (options Profibus DP, Modbus) - Flowphant - Memograph S GLX906A (it) - FML621 nl,fr,it and es - FML621 de and en - Memograph GLB403A - Memograph S GLY303A - TMT142 (tku03xa), TMT162 (tiu03xa) ========================================================================== V1.22.1.0 23.08.2007 Driver updates (only for set-up required) - Memograph M ========================================================================== V1.22.0.0 17.08.2007 New functions/features: - Memograph M supported - FML621 supported - New online help - New manuals Driver updates (only for set-up required) - TMT142/TMT162 (tku03xa/tiu03xa/com_162/com_142) - RMC621 ========================================================================== V1.21.5.0 13.06.2007 Bug fixing / modifications: - Read out stored values / RMM621: fixed a problem when math channels are stored as counters Driver updates (only for set-up required) - RMS621 - RMC621 - RMM621 - Flowphant - ASP2000 - TMT181 (TPC00XA, TPC10XA) and TMT121 (TAU00XA, TAU10XA) ========================================================================== V1.21.4.0 31.01.07 - Setup program modified (new InstallShield version 12.0) - Windows Vista now supported Bug fixing / modifications: - Some internal preparations for new languages Driver updates (only for set-up required) - RIA452 - Ecograph T (Chinese traditional and Portuguese added) - RMC621 - RMS621 - RMM621 ========================================================================== V1.21.3.0 13.12.06 Bug fixing / modifications: - Ecograph T / firmware update: problem fixed caused by unit address <> 01 - RIA452 V2 / firmware update: problem fixed caused Driver updates (only for set-up required) - TMT182, TMT122 and TMT112 - RIA452 V2 - Ecograph T - Memo-Graph GLK900A and Memo-Graph S GLX901A - RMS/RMC621 V3.04.00 ========================================================================== V1.21.2.0 29.09.06 New functions/features: - supported COM ports increased up to 20 - Ecograph T / read out stored data: ReadWin 2000 now stores the total counters Bug fixing / modifications: - Display stored values: fixed a problem caused by a large number power off/on messages (>17000) - Firmware update Ecograph T modified Driver updates (only for set-up required) - ASP2000 Peristaltic - Ecograph T (new languages Chinese and Dutch) - Flowphant - Liquiport 2000 - RIA452 Version 2 - RMC621 - RMM621 - RMS621 - TMT122 - TMT142 - TMT162 - TMT182 ========================================================================== V1.21.1.0 14.07.06 New functions/features: - RMC621: new function: Convert configuration Ex <-> Non-Ex (see Extras -> Special unit functions -> RMC621) - RIA452 Version 2 now supported (at the moment German language only) Bug fixing / modifications: - Read out memory card via interface/modem: fixed a problem caused by some date/time settings - Extras / Service / Release options. Under some circumstances it was not possible to enter an Ecograph T option code - Eco-Graph and Memo-Graph renamed to Ecograph and Memograph (E+H corporate design) - Ecograph T program update improved Driver updates (only for set-up required) - Ecograph T - RMM621 - TMT121, TMT111 - Memograph GLB201A und Memograph S GLY303A ========================================================================== V1.21.0.0 25.04.2006 New functions/features: - RMM621 now supported - Formula editor added (for RMM621) - Print unit setup - Font size increased, new format for level 4 and 5 headers (Ecograph T) - Parameter ID removed (Ecograph T) - Unicode now supported (Ecograph T) - Print out of long parameter texts (RMM621) - New version of ReadWin Quick Setup Temperature added Bug fixing / modifications: - Max. Length of parameter texts increased --> new stg file format (only for RMM621 and new unit types, all old unit types are still compatible) - Readout instantaneous values: - Transmission security improved - Audio alarm (long wav files) fixed - Display of very large values modified - Transmit unit programs modified: - Read out unit id modified (only Ecograph T) - Time out RMx621 increased - Automatic setup: file extensions fixed - Read out stored values modified (only RMM621) - Function to remove empty database folder added (for internal use only) Driver updates (only for set-up required) - ASP2000 SW LDB68XA/LDB69XA - GLB201A - RMC621 - RMS621 ========================================================================== V1.20.0.0 06.02.06 New functions/features: - FlowPhant DTT31/55 released - RMM621 pump control released - Ecograph T: new function "Readout memory card via interface/modem" - Ecograph T: option integration supported Bug fixing / modifications: - Ecograph T / setup: new transmission protocol to read out / transmit the unit setup. This protocol increase the transmission time up to 10 times (specially with GSM modems). Notes: - Ecograph T version 01.01.00 or higher is required. With older version ReadWin 2000 will automatically use the old protocol - ReadWin 2000 can be forced to use the old protocol with the ini file entry "SetupTransmissionMode=0". - Unicode message dialogs added - Memograph: Baud rate 1200 enabled - Ecograph T / read out stored data: wrong flags "under range" and "over range" fixed - Display measured values: new flag "Limit" added (for Ecograph T) - Ecograph T firmware update problem fixed. - Read out measured values: fixed a problem read out "envelope curve" values - Start up checks improved (check access to the data directory) - Display measured values: "1899" problem fixed - Automatic: fixed an error message problem during initialisation - program options: selection list "Automatic interrupted for maintenance purposes" increased to 6 hours - new program option "Measured value data base maintenance "Interval 7 days" - readout/transmit set up via TCP/IP: wrong error message fixed Driver updates (only for set-up required) - Update: ASP2000 - Ecograph T (new option "Intergation") ========================================================================== V1.19.0.0 05.10.05 New functions/features: - Easytemp TMR31/35 added - Ecograph T: East European, North European and Japanese language package added Bug fixing / modifications: - Japanese translation modified - Setup / Ecograph T: fixed a problem when the unit was created with a measurement file: there was a warning that the CPU was different. - RMx621 / Transmit program: fixed a problem, when saving the counter - RIA452 / Transmit program: fixed a problem, when using the RS232/USB box TXU00xA. - Store/Save measure values: fixed a problem which occur when only montly values are stored. Driver updates (only for set-up required) - Ecograph T - RMx621: FCU00xA, FCS00xA - Memograph (S): GLB501A, GLW100A, GLM100A, GLK800A, GLB50AA, GLX10AA - TSU000A, TRU100A, TRU000A, TPC000A, TPC100A, TKU033A, TIU003A, TUI023A, TIU033A ========================================================================== V1.18.2.0 12.08.05 Bug fixing: - Ecograph T setup - export data Driver updates (only for set-up required) - Ecpgraph T - Memograph (S): GLZ10xA, GLK800A, GLX10xA - RMx621: FCS00xA, FCU00xA, FCA20xA - TAU10xA ========================================================================== V1.18.1.0 05.07.05 New functions/features: - read out measured values from Ecograph T: ReadWin 2000 stores the data into the database now about 40 times faster than the old version. Bug fixing: - Ecograph T: Program update modified (the update did not work on old CPUs) ========================================================================== V1.18.0.0 01.07.05 Important notes: - ReadWin 2000 does not support Window 9x, ME and NT 4.0 anymore. - the Ecograph T requires the font "MS Arial Unicode" (which is part of MS Office 2000 and higher) West European languages will work without this font but all other languages will need it! New functions/features: - Ecograph T now supported - Readwin Quick Setup Temperatur modified Bug fixing: Driver updates (only for set-up required) - Bugfix: TMT142 und TMT162 - Update: COM182 für TMT182 Advanced Diagnostics - Update: Liquiport/ASP2000 Peristaltic - Update: ASP2000 ========================================================================== V1.17.2.0 16.03.05 Bug fixing: - "ReadWin Quick Setup Temperature + Switches" updated - Fixed a problem with the installation program - Program update RMS621 FSU00xA to FCS00xA: fixed a version check problem ================================================================================ V1.17.1.2 24.02.05 Driver updates (only for set-up required) - With the versions 1.17.1.0 and 1.17.1.1 it was not possible to set up the RMC621 FCU00xA and RMS621 FCS00xA --> Error 20000 ================================================================================ V1.17.1.1 22.02.05 Driver updates (only for set-up required) - RIA141, RIA452 (English drivers added) ================================================================================ V1.17.1.0 17.02.05 New functions/features: - Setup program updated - new module "ReadWin Quick Setup Temperature + Switches" added - communiction performance improved for temperature units Bug fixing: Driver updates (only for set-up required) - TMT162/142: - Memograph GLG200A - RIA141 - RMC621 ================================================================================ V1.17.0.0 09.12.04 New functions/features: - TMT 142 and TMT 112 now supported - RIA141 and RIA452 now supported - Russian language (note: requires Russian Windows) - Set-up: set-up lock added for units which are in the "enhanced set-up security mode" Driver updates (only for set-up required) - Memograph (S): GLX900A, GLC105A, GLL300A - Thermofant TTR31/35 - Cerafant PTC31 - PTP31/35 - ASP 2000, ASP 2000 Peristaltic - Liquiport 2000 - TMT162: TIU03xa Bug fixing: - Unit set-up: - Some texts modified, translations implemented - Set-up of temperature units: it was not possible do modify the COM port after the unit was created - Display instantaneous values using Client/Server mode: under some circumstances it was not possible to start this function - Mini-Log: Read out stored values via modem: Fixed a problem which could be caused by communication interferences - Export measured values into a text file: under some circumstances the dimension was exported into a wrong column ================================================================================ V1.16.2.0 15.09.04 New functions/features: - Transimt program/RMx621: original diskette check disabled - Modifications for the new RMS621 (based on RMC621) Driver updates (only for set-up required) - RMC621 FCA100xA,FCS001A,FCS002A,FCS003A,FCS004A,FCS006A,FCS007A,FCS008A, FCS00AA, - Memo-Graph GLE903A, GLH601A - TMT162 TIU030A ,TIU031A Bug fixing: ================================================================================ V1.16.1.0 05.08.04 New functions/features: - Display measured values from database / store comment into event list: additional to the entered date/time ReadWin can now also save to storage time (optional; see program options -> set-up -> Display / Print out (2)). Driver updates (only for set-up required) - RMC621 FCU00xA, FCL00xA - Memo-Graph GLK30xA, GLE90xA - Thermophant TTR31/35 - Ceraphant PTC31 - PTP31/35 - TMT181, TMT121, TMT122, TMT182 Bug fixing: - Fixed a problem entering the Z-Matrix in the RMC621 - Some error messages improved (Mini-Log and set up) - Thermophant communication default settings modified - Some spelling mistakes removed - The possibility to change the set up language (introduced in version 1.16.0.0) caused under some circumstances a problem to send the set up to the unit or read out measured values (error message 20020) - Fixed a problem with a T-Mobil GPRS modem ================================================================================ V1.16.0.0 21.06.04 New functions/features: - Thermophant TTR31/35 released - Ceraphant PTC31 - PTP31/35 released - ASP2000 Peristaltic - Japanese language (note: requires Japanese Windows) - the ReadWin 2000 setup language can now be changed: see setup -> extras -> change unit operation language (PC-Software only). Note: this feature is only supported by: Memo-Graph S, all Eco-Graph, RMx621 Driver updates (only for set-up required) - TMT121 (additional sensor type Ni120 (Edison Curve #7)) - Memo-Graph S Drivers from setup program removed: - Memo-Graph: GLB106A, GLB405A, GLB701A, GLB706A, GLC400A, GLC401A, GLC408A, GLD200A, GLE300A, GLE600A, GLE700A, GLG806A, GLH501A, GLH601A, GLH700A Bug fixing: - Setup Mini-Log: problem with presetting the total counter fixed - Transmit program: fixed a problem with some USB/RS232 converters - UMA20xA problem fixed - Memo-Graph/read out measured values from ATA-Flash: automatic unit detection modified ================================================================================ V1.15.1.0 12.03.04 New functions/features: - Batch/Product print out: the line spacing of the signature fields on the right side can now be changed (see program options) Driver updates (only for set-up required) - TSM470: special version for measurement range -50...250°C added - Memo-Graph GLE600A, GLK006A - Mega-Log UNF700A - RMC621 FCA00xA - RMS621 Driver updates - Eco-Graph A and Memo-Graph (S): totalized analog instantaneous values can be displayed now Note: Memo-Graph S: to get totalized mathematic instantaneous values a version larger than V1.01.00 is required Bug fixing: - problem to open connection via Nokia GSM Modem D211 fixed - set up: it was possible the modify choice box values although these values should not be changeable. (this problem was caused by modifications in ReadWin 2000 V1.13.2.0) - it was possible to start the automatic with the F10 shortcut although the menu was disabled - Automatic read out: fixed the problem that some error messages must be confirmed by a user - Mini-Log/read out measured values: invalid comma values will now creating error messages - Selecting units: it is not possible anymore the reduce the group column to a size of zero - Set up / add new unit: under some circumstances it was possible to get some invalid serial default settings ================================================================================ V1.15.0.0 02.02.04 New functions/features: - ReadWin 2000 start screen modified (new E+H Corporate Design) - Automatic read out: new program option added: it's now possible to stop the read out for a selectable time period (within this period it is for example possible to run a backup on a network drive) - new program option: added: Hart communication retries (required for HART units) - Security / user administration: new user right added: Channel selection even without the access right "Display measured value, change channel set-up" - Transmit program: the setup and counter conditions can be read out before a program transmission. After the program transmission these information were send back to the unit. The user can select this feature during the transmit program process (note: this feature is only available if supported by the unit). Driver updates (only for set-up required) - divers Memo-Graph special programs - Eco-Graph C Dutch driver added - RMC621 (new languages) - Liqui-Port 2000 - TMT121, TMT122 - TMT110, TMT121, TMT180, TMT181 - TSM470 Bug fixing: - Display instantaneous values as curves: fixed a problem with was cause by modification in version 1.13.0.0: The feed rate was always 1 second (the selected feed rate was ignored) ================================================================================ V1.14.1.0 10.12.03 New functions/features: - ReadWin 2000 now supports COM ports 1 to 15 - Eco-Graph C ELC20xA now supported - unit set-up / add a new unit: ReadWin 2000 now remembers the last settings Driver updates (only for set-up required) - Memo-Graph S - Eco-Graph C - RMS621 - RMC621 - Liqui-Port 2000 - divers Memo-Graph special programs Bug fixing: - problem on computers with processors with Intel Hyper Threading technology fixed: ReadWin 2000 didn't start anymore - Memo-Graph S login / user administration / remote control: words with special characters (e.g. German umlauts) were not send correctly to the unit - some error messages modified/improved - fixed a problem to import Memo-Graph Waste Water (GLD20xa) stored data from ReadWin 16Bit (*.rdf files) - Eco-Graph C / display instantaneous values: on a 4 channel unit it was not possible to select the channels =============================================================================== V1.14.0.0 29.10.03 New functions/features: - Export measured values from database: csv format now supported Note: the csv format (comma separated format) is anything but standard. There are quite a few variations. Depending on the application you want to use you have to select the right separator (e.g. Excel requires a semicolon) - RMC621 now supported - new program options / security: - User name/password required to close the program - Administrator rights required to close the program =============================================================================== V1.13.2.0 08.10.03 New functions/features: - New Memo-Graph special program added (gld20xa) - Display measured values: default settings Memo-Graph Waste Waster Software (gld10xa) modified Bug fixing: - Read out measured values: problem with "read-only" files fixed - Read out measured values: problem with Russian language units fixed (wrong channel names) - Display instantaneous measured values: problems with decimal separator fixed (occurred only at iTEMP/easytemp units in combination with ReadWin 2000 >= V1.13.0.0) - sporadic problem to load/import measured values (rsd files) from diskette fixed - Set-up/Display units with East European / Asian char sets: it's now possible to show these char sets on West/Middle European PCs (Windows 2000 / XP required) =============================================================================== V1.13.1.0 21.08.03 New functions/features: - Add a new unit: if the automatic unit detection finds a unit, which is not selected under "Extras -> Program options -> Select units used", ReadWin will automatically enable this unit - Export measured values: New column separator added: "Fixed length" (every column has a fixed length) - new drivers von Eco-Graph A - new program option: "Display measured values from database: show minimum/maximum values with date/time" - easytemp TSM 480 now supported - new drivers for TSM470 - Linearisation Add-on for temperature units modified (SMC32.DLL). Help file added. Bug fixing: - Export measured values: If the destination file was already used by another program (e.g. Excel) it was not possible to export data to this file. ReadWin cancelled the export without an error message. - Audit trail: ReadWin now journalise if a user enable/disable the option "Password protection compliant to FDA 21 CFR Part 11" - Display measured values from database / Batch selection: under some circumstances it was not possible to select the last batch from the list. - Display measured values from database / Batch selection: ReadWin is now selecting automatically the newest batch. - Display measured values from database / Measurement cursor: the size of the date/time column has been increased (on some computers it was to small) - Display measured values from database / Save table / Password protection activated: it was possible to run the function "Save table" even if the used did not has the right "export measured values. =============================================================================== V1.13.0.0 23.06.03 New functions/features - ReadWin 2000 can now make the instantaneous values available to other PCs using a network data base so long as these PCs run ReadWin 2000. This means that users that have no direct access to the unit can now see the actual instantaneous values (see program options) - Memo-Graph S: remote control function added - Eco-Graph C Telealarm added - Print out unit set up: additions line "verified:……." added - Export for measured values: additional format settings added - Display measured values: the channels can now be sorted via channel number or channel name (see program options) - Display instantaneous values as curves: the value are now updated every second (independent from the storing cycle) - new program option: "Measured value data carrier (diskette/Ata flash) must NOT be deleted after read out" Bug fixing - Print out measured values: it was not possible to start the print out if there was only one printer installed on the PC =============================================================================== V1.12.0.0 16.04.03 New functions/features - Display archived measured values: for each analogue channel two help lines can be added (--> Legend --> Change channel set up --> Scale / y-Axis). The format of these help lines can be modified via "Display" --> "Set-up". - Display archived measured values: The channel identifier can now be shown in the right hand margin (helpful if using black and white printout). This function can be switched on or off under the menu headings "Display-->Set-up-->y-axis..." - Display/printout archived measured values from the graphics: When the function "Distribute graphics on a number of pages" is active then all pages will be automatically printed out (printer option) - Display/printout archived measured values from the graphics: Using an option it is now possible to force a black/white printout (all colours are set to black for the printout --> should remove some problems with B/W printers) - Display archived measured values: "Power on /power off messages can now be shown in the graphics. Hint: This function only operates on newly read out measured values. ("Power on/power off messages that have already been saved in the data base cannot be displayed). - Tool for repairing data bases added Bug fixing - It was possible that when the unit set-up is protected by a release code that the mouse pointer disappeared after the code was entered. What needs to be done is to click the right mouse key so that the mouse pointer reappears. - If AVI files (animation) were not available or could not be started some other features could not be run, even though they were not relevant to the functions. - Problem on SRAM card recognition removed - Graphic instantaneous display: the channel independent set-up such as feed rate, y-axis distribution are now saved. - Internal driver extension for set-up added =============================================================================== V1.11.0.0 18.03.03 New functions/features - Eco-Graph C is now supported - Special programme GLE80XA built-in - The service function "Unit details -->from data base" can now be selected (using right mouse key) from the unit selection - Measured value display/measured value extort: The digital channel selected are now supported with the information Channel type = "Digital" - Automatic: Memo-Log CMB40xA message receipt built-in - Instantaneous value display: The relays in Memo-Log CMB40xA can now be remote controlled - Store/save measured values: The default file name now also contains the selected storage time range Bug fixing - The database is not re-coded on store/save measured values. The data is however still secured against manipulation by the check sum - The end date is no longer stored/saved on store/save measured values. Exception is: on time selection "complete time scale" and "Presettable" (Here the data is stored/saved including the end date) - Memo-Graph S / Memo-Graph GLC10xA measured value display: It was possible to select the option "Select Product/Batch" if only "Same as unit graphics" data are available and no intermediate analysis. In this case fault message 20104 (data base 'SPC...db' could not be opened!) would appear. The same error massage appeared on the function "Printout Batch/Product". - Automatic: If the option "Start automatic after ... minutes" was switched on and the automatic has been started, it could happen that the automatic was restarted, if ReadWin was minimised and then maximised again. - Mini-Log B Readout/display measured values: The start time of a storage cycle on the digital channel was not saved. This was no problem as long as the analogue and digital channel were simultaneously displayed. If only the digital channel was displayed the first measured value was not displayed in the graphic. Comment: If data was imported from the 16Bit ReadWin version the first digital value cannot be graphically displayed as the start time was not stored in the 16Bit ReadWin version. - Measured value display: If 40 channels are displayed then the events list was not displayed - Measured value display on Eco-Graph: The engineering unit "s" was transmitted on operating times - Communication via modem: the telephone number can now contain the character "," =============================================================================== V1.10.1.1 13.01.03 New functions/features - new unit drivers: TMT 162 TIU02xA, RMS621 FSA00xA and Alpha-Log BAA00xA =============================================================================== V1.10.1.0 10.12.02 Bug fixing - TMS 470 setup problem fixed - Time syncronisation now supports Memo-Graph GLUx00xA (>= V2.62) =============================================================================== V1.10.0.0 21.11.02 New functions/features - easytemp TSM 470 added - LinTab32 expanded: Total volume can now be entered directly (option) - Batch/product printout: The fields to be printed out or displayed can now be set up using the programme. Additionally the field idents can be user defined. - Batch/product printout: In addition to the graphic or event list the respective analysis can also be printed out (must be activated during program options --> set up). - Mini-Log RLU30xA added - Printout of stored measured values: Page numbers reworked - Automatic: Time synchronisation PC --> Unit added (muss be activated: unit set up --> Extras --> Set up automatic --> Time synchronisation). Note: only available if supported by the unit. - Memo-Graph S >= V1.00.11 - Eco-Graph >= V2.00.10 - Eco-Graph A >= V1.00.10 - Eco-Graph C >= V1.00.00 - The unit address can now be entered at HART units - Debug logging function added (for internal use only) - Read out stored data from data carrier: different set up / data combination on the same ATA-Flash can now be handled by ReadWin 2000 (only available if supported by the unit) - RMS621 FSA006A added Bug fixing - No all labels were translated in "Change password" - More data than was necessary was saved under the set-up "Maintenance: Save data on data carrier" + "Save all data since last automatic storage" (the last storage time was only taken into account on automatic start) - Save measured values: added additional error messages - Measured value printout: If print margins were entered in inches these were reset to 0 on next printout - Some internal DLL interfaces modified to fit to HART units - Read out stored values form Mega-Log Tx: if all digital channels are switch off an error message 30000 could appear - Memo-Graph S: with activated read cover it was not possible to read out stored or instantaneous values =============================================================================== V1.9.1.1 25.09.02 Bug fixing - iTEMP TMT162 =============================================================================== V1.9.0.0 27.08.02 New functions/features - iTEMP TMT162 now supported Bug fixing: - Update Eco-Graph A driver =============================================================================== V1.8.4.0 31.07.02 New functions/features - Automatic: the jobs be started manually now (right mouse button) - Print out measured values: ReadWin 2000 can store entered comments. This function must be activated: program options -> set-up -> display / print out (1) -> store entered comments (default = off). Note: the comment is stored unit independent Bug fixing: - Store/save measured values: fixed a problem which can appear under some circumstances (e.g. not enough free hard disk space) =============================================================================== V1.8.3.0 17.07.02 New functions/features - RMS621: display instantaneous values for now available (RMS621 V1.01.01 or higher required) Bug fixing: - Print out of measured values: documents with more than one page were not printed on some HP printers / Win95 correctly (only the first page was printed correctly) =============================================================================== V1.8.2.0 10.07.02 New functions/features - Eco-Graph A now supported - Semiautomatic tank linearisation for RMA422 - Set up / Memo-Graph S: if the unit is sealed by a rear panel, it isn't possible to send the set up or a program update to the unit (Memo-Graph S Version 1.00.01 or higher required) Bug fixing: - Program update RMS621 wasn't available - Set-up / create a new unit: the RMS621 wasn't detected by the automatic unit detection - Display measure values / Memo-Graph: if the group operating mode was set to "Block diagram" the maximum value wasn't displayed - Export stored values / attach data to existing files: ReadWin doesn't create an empty line between the old and the new data anymore ============================================================================= V1.8.1.0 06.06.02 New functions/features - Option: password protection compliant to FDA 21 CFR Part 11 (see program options --> security) Bug fixing: - It wasn't possible to activate the Mega-Log Tx ============================================================================= V1.8.0.0 04.06.02 New functions/features - Memo-Logs S CMB906A now supported - Mega-Log Tx now supported (ULU00xA, UNU00xA, UMU00xA, UMA20xA, UME40xA) - Tank linearisation add-on now available (RIA250, RMA421 and RMA422) - Display measured values from database: print out of batch/product overview Bug fixing: - problem in the set-up of CMB20xA/ CMB40xA fixed - problem when importing stored Memo-Log data from the old ReadWin fixed ============================================================================= V1.7.1.0 07.05.02 Bug fixing: - Read out Mini-Log problem solved ============================================================================= V1.7.0.0 30.04.02 New functions/features - RMS 621 units are now supported. Attention: If ReadWin 2000 is already being used then the RMS 621 unit must be activated. (Extras --> Programme options --> Select units used) - Eco-Graph Version 2 now supported - Memo-Log S (CMA20xA, CMB20xA und CMB40xA) units are now supported. Attention: If ReadWin 2000 is already being used then the Memo-Log S unit must be activated. (Extras --> Programme options --> Select units used). Note: The Memo-Log S remote control function is not supported yet) Bug fixing: - It was not possible to load demo data from a read-only medium (e.g. CD-ROM) --> error message 30000 (only Version >= V1.5.0.0) - Displaying stored data from database: It was possible to select the "batch function" even when more than one unit as selected - Import of Mini-Log data from ReadWin 16Bit: the dimension and comma position of the digital input were not imported correctly ============================================================================= V1.6.0.0 08.04.02 From this software version you can use a new optimised database. You can still use the original database, but it is strongly recommended to run a data base reorganisation. In order to do this call up the following in the main menu --> "Extras" --> "Service" --> "Data base maintenance" and then the function "Reorganise data base". Please read the notes that appear after starting the function "Reorganise data base"! New functions/features - Memo-Log units are now supported. Attention: If ReadWin 2000 is already being used then the Memo-Log unit must be activated. (Extras --> Programme options --> Select units used). Note: Memo-Log S and Memo-Logs S Rüb are not supported yet - The ReadWin 2000 font can be changed now. Note: this setting has no effect on menus, titles or message boxes (the are controlled by the Windows desktop settings) - Remote control ASP 2000 and Liqui-Port 2000 - Unit details can now be shown from units out of the database (Extras --> Service --> Show unit details --> from the database) - Readout measured values of one unit from more the one PC: the ini entry "DefaultReadOutMode" has no effect on newer unit types anymore (e.g. Memo-Graph, Eco-Graph). For these units you should use the unit set-up property "Read out PC x". ============================================================================= V1.5.1.0 15.03.02 New functions / features: - Memo-Graph S units are now supported. Attention: If ReadWin 2000 is already being used then the Memo-Graph S unit must be activated. (Extras --> Programme options --> Select units used) Bug fixing: - If a unit was created only by a data diskette and later on the unit set-up was updated via serial interface then ReadWin 2000 didn't store the communication settings. - Display audit trail data: there was a checksum warning when the event "Audit trail data imported" was displayed - Liqui-Port 2000 / ASP 2000 display/readout measured values: under some circumstances a checksum warning was shown when displaying event messages. - Show unit details (service): it was always possible to select all communication types (independent from the selected unit types) ============================================================================= V1.5.0.0 01.03.02 New functions / features: - Audit Trail functions - Error messages and received messages from the unit can now be send to different email addresses - Display measured values: the main axis can now be easily changed with a right mouse click in the legend - Patch/product print out (note: use the CTRL-Key to select more than on batch) - iTEMP TMT 110 - French operating manual - New program option: "Printout: Start new print task for each new side". Some printer drivers have problems when ReadWin 2000 what to print more than one page per print task (only the first page is printed). In this case activate this option. - New program option: "End modem connection swiftly". Some modems (especially GMS Modems) need more time to close a modem connection. If ReadWin 2000 is reconnecting too early no connection can be build up. In this case deactivate this option Bug fixing: - Automatic export of data: under some circumstances it was possible that the were two dots in the file name. This may cause some loading problems in MS Access - Display instantaneous values: it was not possible to change the zoom of math channels - Disconnection modem connection: Exception C0000008 removed - Release code for TMT 180, 181 and 121 now changeable again - Display instantaneous values: Fixed problem when displaying data from more than one unit at the same time using RS485 ============================================================================= V1.4.0.0 05.02.02 New functions / features: - Alpha-Log units are now supported. Attention: If ReadWin 2000 is already being used then the Alpha-Log unit communication must be activated. (Extras --> Programme options --> Select units used) - Instantaneous value display (bargraph and graphic): Zoom can now be set up. - ASP 2000 with ring memory now supported Bug fixing: - Measured value display / Mini-Log: If comments are entered into the events list, these are only displayed when the programme is restarted. - Instantaneous value display / Mini-Log: If the digital input is set to "ON/OFF" events, these are not displayed. - Mini-Log set-up: Some set-up combinations are blocked: e.g. Integration, when the analogue channel is switched off or external storage is used, when the digital channel is switched off. - Set-up: If the programme release code is set all other text inputs are also coded using a password character (e.g. Address 21G8 on Memo-Graph). - Some data base error messages can stop the Automatic. During the automatic readout these messages are now also entered into the events list. ============================================================================= V1.3.0.0 27.11.01 New functions / features: - Mini-Log B now available (RLU00xA und RL200xA) - iTEMP HART TMT 122 now available - Operating manual/on-line help in Italian and Spanish are available. - Automatic batch printout after manual read out (so long as this function is active in the programme set-up and printout is active in the automatic set-up) - Automatic measured value export after manual read (so long as this function is active in the programme set-up and export is active in the automatic set-up) - Measured value display: x/y-Zoom is now available (can be switched on in set-up). Default: only x-Zoom - Measured value read out: Monitoring the unit being read out has been increased; this means that channel and group settings are compared with those in the unit stored on the data base. - Instantaneous value display: the remote monitoring function (only GLE10xA) can now be locked (using the user administration) - Read out: Supported by Memo-Graph text messages (Memo-Graph GLUxxxA >= V2.40 required) - The default set-up for "Unit set up --> Store set up into unit data base " can now be generated in different forms (Name or Name + CPU-No or Name + Date/time). See programme set-up. - Add new unit: Depending on unit type the unit address and release code are displayed or not. Bug fixing: - Measured value export: When adding data to existing data the header (Channel identifier, engineering units, etc.) is only created when "Create header" is active. - Unit set-up: On some parameters (e.g. channel engineering units) could not contain a "Space" or the units could not be directly entered (at least 1 space must be entered). ============================================================================= V1.2.2.0 08.10.01 New functions / features: - iTEMP TMT180 and TMT121 now supported - Label printer for iTEMP TMT 121/180/181/182 - y-axis for digital signals (on/off) Bug fixing: - Modification of the modem connection - Displaying instantaneous values: Fixed a problem if one unit was connected via TCP/IP and another via serial interface (Error 20020) ============================================================================= V1.2.1.0 30.08.01 New functions / features: - iTEMP TMT180 and TMT121 now supported (internal Beta-Versions) - Reorganization of the VCom communication - The default colours of analogue and digital channel can be changed now - Unit set-up: new function "Store set-up into unit data base as..." - New language Polish Bug fixing: - Set-up dialogue: fixed the problem that the unit address and the release code now were reset - Unit set-up: if the dialogue for entering the interface settings was opened the unit address and the release code were set to there default settings - Database conversion: fixed the error message "Fehler beim Lesen von dir_DBLocation.DriveTypes: Fehler bei Bereichsprüfung" ============================================================================= V1.2.0.0 03.08.01 New functions / features: - Automatic data base conversion - Danish operating manual and online help available Bug fixing: - Instantaneous value display: Impulse counter was not displayed (only on German Memo-Graph) - Batch description entry using ReadWin 2000: Description and name were swapped - Measured value import (*.rsd): If data is stored in duplicate it could lead to the fault message "20102 - Error in writing to data base! (Modul: Tdm_Main.ImportData (2)). - For some unknown reason the E-mail components could not be set up on some Win95 PCs. The error message "10095: Successful WSAStartup not yet performed" appears. This problem has the consequence that the dialogue "Set up", "Automatic set up" and the "Automatic" cannot be started. This error seems to be caused by an incompatible Windows-DLL. The e-mail function of ReadWin 2000 is therefore not available on these PCs. This problem has, however, been cleared as far as possible so that the above mentioned dialogues can be called up. - Unit set up print out: CPU-No was not printed out, from page 2 some lines were printed out using the incorrect font size. - Import of stored data (Load measured values): some errors removed - some minor bugs removed ============================================================================= V1.1.0.0 02.07.01 New functions / features: - new option (programme set-up): "Use main dialogue background gradient". Default: on - new option (programme set-up): "Automatically delete measured values from data carrier (diskette/Ata Flash) after read out". Default: off - Label versions only: Some default values have been changed - Label versions only: the dialogue "Select units used" does not longer appear at the first start up of ReadWin 2000. Labelled units will now be automatically selected. - Display measured values from database / channel selection: new button "Add all" Bug fixing: - the error "Exception in module Tdlg_Status.tmr_MainTimer" fixed. This error only appears under this constellation: Win NT, Automatic mode, communication with Modem and ReadWin 2000 is running in background ============================================================================= V1.0.0.0 05.06.01 Release =========================================